CUBIC PM2005/PM2105 Laser Particle Sensor Module

The pm2005 sensor platform allows you to use your PM2005/PM2105 laser particulate matter sensor with ESPHome.

Image
CUBIC PM2005/PM2105 Laser Particle Sensor Module.

The sensor communicates with the board via the I²C protocol.

# Example configuration entry
sensor:
  - platform: pm2005
    update_interval: 60s
    pm_1_0:
      name: "PM1.0"
    pm_2_5:
      name: "PM2.5"
    pm_10_0:
      name: "PM10.0"
    aqi:
      name: "Air Quality Index"
      calculation_type: AQI

Configuration variables

  • type (Optional): pm2005 (default) or pm2105

  • update_interval (Optional, Time): The interval to check the sensor. Defaults to 60s.

  • pm_1_0 (Optional): Use the concentration of particulates of size less than 1.0µm in µg per cubic meter.

  • pm_2_5 (Optional): Use the concentration of particulates of size less than 2.5µm in µg per cubic meter.

  • pm_10_0 (Optional): Use the concentration of particulates of size less than 10.0µm in µg per cubic meter.

  • aqi (Optional): Air Quality Index sensor. Requires both pm_2_5 and pm_10_0 sensors to be configured. See PMSX003 Particulate Matter Sensor for more details.

    • calculation_type (Required): The AQI calculation standard to use. One of: AQI (US EPA) or CAQI (European).
    • All other options from Sensor.